== sanity-pfl test 19e: Replay of layout instantiation & extension ========================================================== 04:07:30 (1780992450) striped dir -i1 -c2 -H crush2 /mnt/lustre/d19e.sanity-pfl UUID 1K-blocks Used Available Use% Mounted on lustre-MDT0000_UUID 2210304 3072 2205184 1% /mnt/lustre[MDT:0] lustre-MDT0001_UUID 2210432 2816 2205568 1% /mnt/lustre[MDT:1] lustre-OST0000_UUID 3771392 19456 3737600 1% /mnt/lustre[OST:0] lustre-OST0001_UUID 3771392 17408 3751936 1% /mnt/lustre[OST:1] filesystem_summary: 7542784 36864 7489536 1% /mnt/lustre 1+0 records in 1+0 records out 4194304 bytes (4.2 MB, 4.0 MiB) copied, 0.185057 s, 22.7 MB/s before MDS recovery, the ost fid of 2nd component is [0x2c0000408:0x201:0x0] Failing mds1 on oleg144-server Stopping /mnt/lustre-mds1 (opts:) on oleg144-server 04:07:42 (1780992462) shut down facet: mds1 facet_host: oleg144-server facet_failover_host: oleg144-server Failover mds1 to oleg144-server mount facets: mds1 Start mds1: mount -t lustre -o localrecov lustre-mdt1/mdt1 /mnt/lustre-mds1 oleg144-server: oleg144-server.virtnet: executing set_default_debug vfstrace rpctrace dlmtrace neterror ha config ioctl super lfsck all pdsh@oleg144-client: oleg144-server: ssh exited with exit code 1 Started lustre-MDT0000 04:08:17 (1780992497) targets are mounted 04:08:17 (1780992497) facet_failover done oleg144-client.virtnet: executing wait_import_state_mount (FULL|IDLE) mdc.lustre-MDT0000-mdc-*.mds_server_uuid mdc.lustre-MDT0000-mdc-*.mds_server_uuid in FULL state after 0 sec after MDS recovery, the ost fid of 2nd component is [0x2c0000408:0x201:0x0]