== insanity test 12: Twelve Failure Mode: MDS0,MDS1/OST0, OST1/CLIENTS Thu Sep 10 10:46:40 EDT 2026 ========================================================== 10:46:40 (1789051600) Verify Lustre filesystem is up and running Failing mds1 on oleg435-server Stopping /mnt/lustre-mds1 (opts:) on oleg435-server Failing mds2 on oleg435-server Stopping /mnt/lustre-mds2 (opts:) on oleg435-server 10:46:50 (1789051610) shut down facet: mds1 facet_host: oleg435-server facet_failover_host: oleg435-server facet: mds2 facet_host: oleg435-server facet_failover_host: oleg435-server Failover mds1 to oleg435-server mount facets: mds1 Failover mds2 to oleg435-server mount facets: mds2 Start mds1: mount -t lustre -o localrecov /dev/mapper/mds1_flakey /mnt/lustre-mds1 Start mds2: mount -t lustre -o localrecov /dev/mapper/mds2_flakey /mnt/lustre-mds2 oleg435-server: oleg435-server.virtnet: executing set_default_debug vfstrace rpctrace dlmtrace neterror ha config ioctl super lfsck all oleg435-server: oleg435-server.virtnet: executing set_default_debug vfstrace rpctrace dlmtrace neterror ha config ioctl super lfsck all pdsh@oleg435-client: oleg435-server: ssh exited with exit code 1 pdsh@oleg435-client: oleg435-server: ssh exited with exit code 1 Started lustre-MDT0001 Started lustre-MDT0000 10:47:22 (1789051642) targets are mounted 10:47:22 (1789051642) facet_failover done oleg435-client.virtnet: executing wait_import_state_mount (FULL|IDLE) mdc.lustre-MDT0000-mdc-*.mds_server_uuid,mdc.lustre-MDT0001-mdc-*.mds_server_uuid 1475 0 mdc.lustre-MDT0000-mdc-*.mds_server_uuid in FULL state after 0 sec mdc.lustre-MDT0001-mdc-*.mds_server_uuid in FULL state after 0 sec Failing ost1 on oleg435-server Stopping /mnt/lustre-ost1 (opts:) on oleg435-server Failing ost2 on oleg435-server Stopping /mnt/lustre-ost2 (opts:) on oleg435-server 10:47:48 (1789051668) shut down facet: ost1 facet_host: oleg435-server facet_failover_host: oleg435-server facet: ost2 facet_host: oleg435-server facet_failover_host: oleg435-server Failover ost1 to oleg435-server mount facets: ost1 Failover ost2 to oleg435-server mount facets: ost2 Start ost2: mount -t lustre -o localrecov /dev/mapper/ost2_flakey /mnt/lustre-ost2 Start ost1: mount -t lustre -o localrecov /dev/mapper/ost1_flakey /mnt/lustre-ost1 seq.cli-lustre-OST0001-super.width=65536 seq.cli-lustre-OST0000-super.width=65536 oleg435-server: oleg435-server.virtnet: executing set_default_debug vfstrace rpctrace dlmtrace neterror ha config ioctl super lfsck all oleg435-server: oleg435-server.virtnet: executing set_default_debug vfstrace rpctrace dlmtrace neterror ha config ioctl super lfsck all pdsh@oleg435-client: oleg435-server: ssh exited with exit code 1 pdsh@oleg435-client: oleg435-server: ssh exited with exit code 1 Started lustre-OST0001 Started lustre-OST0000 10:48:17 (1789051697) targets are mounted 10:48:17 (1789051697) facet_failover done oleg435-client.virtnet: executing wait_import_state_mount (FULL|IDLE) osc.lustre-OST0000-osc-[-0-9a-f]*.ost_server_uuid,osc.lustre-OST0001-osc-[-0-9a-f]*.ost_server_uuid 1475 0 osc.lustre-OST0000-osc-[-0-9a-f]*.ost_server_uuid in FULL state after 0 sec osc.lustre-OST0001-osc-[-0-9a-f]*.ost_server_uuid in FULL state after 0 sec Failing 2 CLIENTS Request fail clients: 2, to fail: 0, failed: 0 No clients failed! Test Lustre stability after CLIENT failure Reintegrating CLIENTS